Toxic Gas Detectors

signaline-heat-tinyBased on Elecrochemical technique Toxic Gas sensor Based on NDIR technique Greenhouse Gas sensor

» TX-FH
• 2 wire transmitter
• Analog display
• Using remote type sensor
• Without display (FH-N)
• With digital display (FH-D)

» TX-FMD
• 2 wire transmitter
• Digital Display
• Using GS-DX/DY type sensor
• With analog display (FM)
• Without display (FN)

» TX-DP-A
• 2 wire transmitter
• Analog display
• Using GS-DP type plug in sensor
• With digital display (DP-D)
• Without display (DP-N)

» TX-EP-A
• 2 wire transmitter
• Analog display
• Using GS-EP type plug in sensor
• With digital display (EP-D)
•Without display (EP-N)

» STX-PA
• Smart type
• LCD display (Gas name & concentration)
• Local visual alarm
• Alarm relay contacts SPDT x 2
• Alarm relay contact SPDT x 1
• Remote type sensor

» STX-PA-NRD
• Smart type
• LCD display (Gas name & concentration)
• Alarm relay contacts SPDT x 2
• Alarm relay contact SPDT x 1
• Non-remote type GS-DP sensor

» STX-PA-NRE
• Smart type
• LCD display (Gas name & concentration)
• Local visual alarm
• Alarm relay contacts SPDT x 2
• Alarm relay contact SPDT x 1
• Non-remote type GS-EP sensor

» TX-RS
• Smart type
• LCD display (Gas name & concentration)
• Modbus output
• Alarm relay contacts SPDT x 2
• Alarm relay contact SPDT x 1
• Both available for Remote and Non-remote type sensor

» TX-3350ExP-E-D For GS-DP sensor
• 2 wire transmitter
• Digital display
• Using GS-DP type plug in sensor
• Ex-proof type

» TX-3350ExP-E-D
• 2 wire transmitter
• Digital display
• Using GS-EP type plug in sensor
• Ex-proof type

» SH-1000HT-D
• LED Display
• Built in system status function
• Same compact size for NF3, PFC detecting
• DC24V Operation
• Using GS-HT-J/ET-J sensor
• Both on & off site calibration
• Optionally available following models
• With replay SH-1000HT-R

»SH-1000GT
• Analog display
• Same compact size for NF3, PFC detecting
• DC24V Operation
• Using GS-HX/HY/EP sensor

» SH-1400TW-FL
• Same compact size for NF3, PFC detecting
• Analog display
• DC24V Operation
• Using GS-HX/HY/EP sensor

» SH-1000PA
• Stand-Alone Gas detection system
• LCD display (Gas name & concentration)
• DC 4-20 mA output
• Local audio & visual alarm
• Alarm & error relay contacts
• AC 100-240V operation
• Using By-pass flow - Quick detecting System status
• Disconnect sensor
• Low electrolyte level of sensor
• Lose of sample flow
• Filament failure
• Using GS-HY/EP sensor

» SH-1007EXW-GT
• Digital display
• DC24V Operation
• Using GS-HX/HY/EP sensor
• Ex-proof type

» SH-4600IR
• N2O 0-300 ppm (Alarm point 50ppm)
• LCD display
• Local audio/visual alarm
• Alarm and error relay contacts
• Wall mount type
• AC100-240V operation

» SH-4700IR
• CF4 0-500 ppm (Alarm point 100ppm)
• LCD display
• Local audio/visual alarm
• Alarm and error relay contacts
• Wall mount type
• AC100-240V operation

» SH-4500IR
• SF6 0-1000 ppm (Alarm point 200ppm)
• LCD display
•Alarm and error relay contacts
•Wall mount type
• AC100-240V operation
• Alarm and error relay contacts

» TG-XTM-A
• When sensor is changed, it is automatically changed target gas, range, alarm level.Using GS-HS/ES sensor
• LCD display
• Local visual alarm
• Panel mount type
• AC100-240V operation

»TG-TEB
• When sensor is changed, it is automatically changed target gas, range, alarm level.
• Using GS-HS/ES sensor
•LCD display
•Local visual alarm
•AC100-240V operation

» MiniBA
• When sensor is changed, it is automatically changed target gas, range, alarm level.
• Using GS-HS/ES sensor
•LCD display
•Local visual alarm
• Alarm and error relay contacts
• AC100-240V and rechargeable battery operation

» TG-4600TEB-IR
• N2O 0-300 ppm (Alarm point 50ppm)
• LCD display
• Local visual alarm
• Alarm and error relay contacts
• AC 100-240V operation

» TG-4700TEB-IR
• CF4 0-500 ppm (Alarm point 100ppm)
• LCD display
• Alarm and error relay contacts
• AC100-240V operation
• Local visual alarm

» TX-FMD
• 2 wire transmitter
• Digital Display
• Using GS-DX/DY type sensor
• With analog display (FM)
• Without display (FN)

» TG-4500TEB-IR
• SF6 0-1000 ppm (Alarm point 200ppm)
• LCD display
• Local visual alarm
• Alarm and error relay contacts
• AC100-240V operation

»TG-2100TEB-IR
• IPA 0-2% monitor
• LCD display
• Local visual alarm
• Alarm and error relay contacts
• DC24V operation

» TX-1100FK
• Oxygen deficiency detector (0-25% O2)
• Using Limited current Zirconium Oxide sensor
• Analog display
• With digital display (FK-D)

» EX-2300K
• 3 wire transmitter
• Digital display
• 0-100%LEL
• Ex-proof type

» FP-424C
• 3 wire transmitter
• Non display
• 0-100%LEL
• Ex-proof type

» N FPA
• AC 110 or 220V (*1) operation with buzzer
• Please indicate which voltage when order.
• It is possible for controller card RX-1GC to install from 1ch. to 9 ch.
• Alarm 1,2 relay contacts (dry c)
• Error relay contacts (dry b Fail Safe action)
• Isolated 4-20 mA analog output

» N FPO
• DC24V operation without buzzer
• It is possible for controller card RX-1GC to install from 1ch. to 10 ch.
• Alarm 1, 2 relay contacts (dry c)
• Error relay contacts (dry b Fail Safe action)
• Isolated 4-20 mA analog output

» RX-16DN
• DC24V operation
• 16 points 4-20 mA input
• 16 points indication
• Display one selected channel
• Device Net digital communication
• Common alarm 1 ,2 relay contacts
• RC-232C Front maintenance port

» 1GWA/V70
• For single channel wall mount controller
• AC 110, 220V operation with buzzer
• Alarm 1, 2 relay contacts (dry c)
• Error relay contacts (dry b Fail safe action)
• Isolated 4-20 mA analog output

» 6FWA-M
• AC 110 or 220V (*1) operation with buzzer
• Please indicate which voltage when order.
• It is possible for controller card RX-1GC to install from 1ch. to 6 ch.
• Alarm 1, 2 relay contacts (dry c)
• Error relay contacts (dry b Fail Safe action)
• Isolated 4-20 mA analog output

» 9FRA
• AC 110 or 220V (*1) operation with buzzer
• Please indicate which voltage when order.
• It is possible for controller card RX-1GC to install from 1ch. to 9 ch.
• Alarm 1, 2 relay contacts (dry c)
• Error relay contacts (dry b Fail Safe action)
• Isolated 4-20 mA analog output

» 10FRA
• DC24V operation without buzzer
• Please indicate which voltage when order.
• It is possible for controller card RX-1GC to install from 1ch. to 10 ch.
• Error relay contacts (dry b Fail Safe action)
• Isolated 4-20 mA analog output
• Alarm 1, 2 relay contacts (dry c)

» SH-2100IR
• IPA 0-2% monitor
• LCD display
• Local audio/visual alarm
• Alarm and error relay contacts
• Wall mount type
• DC24V operation

Pollution Protection Systems Mumbai Pvt. Ltd (PPSMPL) Company established in “1994”. PPSMPL Designs, develops, manufactures and supplies highly reliable, cost effective instruments and systems as well as services for Gas Detection and Monitoring. Apart from systems suppliers PPSMPL also provides solutions

Contact Us

: +91-998 7522 984

: paraag@ppsmumbai.com

Follow Us